Leave Your Message
Products Categories
Featured Products

12W Medical Power Adapter LXCP12S: Premium, safe, and dependable power supply for medical equipment.

Key points covered:

Power rating (12W)

Medical-grade certification implied by "Medical"

Emphasis on quality, safety, and reliability

Target application (medical devices)

  • Model: LXCP12S
  • DC output voltage: 3.6-15Vdc
  • Peak Power Output: 34W
  • Size(mm): 45.0(L)*40.2(W)*23.2(H)

product detail

detil

Apex is a company specializing in the manufacture of high-performance radio frequency (RF) and microwave filters, committed to providing customers with excellent solutions. Our products cover a frequency range from 10MHz to 67.5GHz, meeting the needs of various industries, including public safety, communications and military. We provide a variety of filter types, including bandpass filters, low-pass filters, high-pass filters and band-stop filters, ensuring that they can meet the requirements of different application scenarios.

Our filter design focuses on low insertion loss and high rejection characteristics to ensure efficient and reliable signal transmission. High power handling capabilities enable our products to operate stably under extreme conditions and are suitable for demanding application environments. In addition, our filters have a compact size, which is easy to integrate into a variety of devices, saving space and improving the overall performance of the system.

Apex uses a variety of advanced technologies for filter design and manufacturing, including cavity technology, LC circuits, ceramic materials, microstrip lines, spiral lines and waveguide technology. The combination of these technologies enables us to produce filters with excellent performance and strong adaptability, which can effectively suppress unwanted frequency interference and ensure signal clarity and stability.

We know that each customer’s needs are unique, so Apex also provides custom design services. Our engineering team will work closely with customers to understand the requirements of their specific applications and provide tailored solutions to ensure optimal performance and reliability. Whether in harsh environments or high-frequency applications, our filters can perform well and meet customer expectations.

Choosing Apex, you will get not only high-performance RF and microwave filters, but also a trusted partner. We are committed to helping you stand out in a competitive market through innovation and excellent customer service.

dafasf

sdaasadasdasd

INPUT CHARACTERISTICS


1. Input Voltage:

Nominal voltage:100-240Vac

Voltage range:90-264Vac

 

2. Input Frequency:

Nominal frequency:50/60Hz

Frequency range:47-63Hz

 

3. Input Current: 0.5A Max. at 90Vac input and rated load.

 

4. Inrush Current:

Output rated load and ambient temperature 25℃, maximum inrush current less than 80A after 50µs at 264Vac input cold start.

 

5. AC Leakage Current:

Normal touch current less than 0. 1mA at 264Vac input.

Single fault touch current less than 0.5mA at 264Vac input.

OUTPUT CHARACTERISTICS


1. Output Power


Model name Output voltage(V)  Rated load(A) Output voltage range(V) Output power(W)
LXCP12S-036bbbcd 3.6  02.40 3. 104.10 08.6
LXCP12S-042bbbcd 4.2  02.40 3.704.70 010. 1
LXCP12S-050bbbcd 5.0  01.20 4.405.60 06.0
LXCP12S-050bbbcd 5.0  02.40 4.405.60 012.0
LXCP12S-060bbbcd 6.0  01.00 5.406.60 06.0
LXCP12S-060bbbcd 6.0  02.00 5.406.60 012.0
LXCP12S-070bbbcd 7.0  01.71 6.407.60 012.0
LXCP12S-075bbbcd 7.5  01.60 6.908.10 012.0
LXCP12S-080bbbcd 8.0  01.50 7.408.60 012.0
LXCP12S-084bbbcd 8.4  01.43 7.809.00 012.0
LXCP12S-090bbbcd 9.0  01.33 8.409.60 012.0
LXCP12S-100bbbcd 10.0  01.20 9.4010.60 012.0
LXCP12S-120bbbcd 12.0  01.00 11.4012.60 012.0
LXCP12S-126bbbcd 12.6  00.95 12.0013.20 012.0
LXCP12S-135bbbcd 13.5  00.89 12.9014.10 012.0
LXCP12S-142bbbcd 14.2  00.85 13.4015.00 012.0
LXCP12S-150bbbcd 15.0  00.80 14.2015.80 012.0
Line regulation ±3%
Load regulation ±5%

2. Ripple And Noise:
Test conditionsUnder 220Vac input,nominal voltage and rated load, the ripple and noise are less than 200mVp-p when measure with Max. Bandwidth of 20MHz and parallel 10uF+0. 1uF, connected at testing point.


3. Turn On Delay Time: 3 seconds Max. at 220Vac input and output rated load.


4. Rise Time: 40ms Max. at 115Vac input and output rated load.


5. Hold Up Time:5ms Min. at 115Vac input and output rated Load.


6. Efficiency: 70% Min. at 115/230Vac input voltage, rated load Test USB end of power supply.


PROTECTION FUNCTION


1. When the output short circuit,the power supply will be protected. 
After the short fault is removed,the power supply will be automatically recovery.


2. Over Current Protection: When the output current reaches 110%200% of the rated current,the power supply will be protected. After the over current fault is removed,the power supply will be automatically recovery.


3. Over Voltage Protection: When the output voltage reaches 105%125% of the rated voltage,the power supply will be protected and can resume normal work after the fault removed.


4. Over TEMP Protection: The power supply shall go into stop mode when the IC's temperature is over its trigger point and when IC temperature is lower than regulation value, the power supply shall be self-recovering.


ENVIRONMENTAL REQUIREMENT


1. Operating Temperature: 0℃~+40℃,Rated load, Normal operation.

2. Storage Temperature: -40℃~+80℃, No work.

3. Storage Humidity: 5%~95%RH, No condensation.

4. Relative Humidity: 10%~90%RH, No condensation.

5. Atmospheric Pressure: 54~106kPa, Normal operation.

6. Altitude: 5000m, work temperature descend 1℃ every 300m over 5000m.

7. Vibration:

    Test standards: IEC60068-2-6 GB/T 2423.10

    5~9Hz, Amplitude of vibration=1.5mm

     9200Hz, Acceleration=5m/s2

8. Transportation

    5~9Hz, Amplitude of vibration=3.5mm

    9~200Hz, Acceleration=5m/s2

    200~500Hz, Acceleration=15m/s2

9. Axial Vibration: 

    Axes, 10 cycles per axis.

    No permanent damage may occur during testing.

    The power supply can be recovery to normal after power off/on.

10. Drop Test: Drop height is 1000±10mm(The table of testing is concrete or the hard wood of 50mm±5mm thick,hardwood density > 600 kg/m³ ).

 

MTBF


The power supply shall have a minimum predicted MTBF(MIL-HDBK-217F) of 100000 hours at normal operation condition and normal use.


ELECTROMAGNETIC COMPATIBLITY


Number Item Test Condition Class Standards
1 CE Class B / IEC/EN60601-1-2;
YY9706. 102;
GB4824;CISPR
11;EN55011;
FCC Part 18.
2 RE Class B / IEC/EN60601-1-2;
YY9706. 102;
GB4824;CISPR
11;EN55011;
FCC Part 18.
3 SURGE Line to line ± 1kV A IEC/EN60601-1-2;
YY9706. 102;
IEC/EN61000-4-5;
GB/T 17626.5.
Line to Earth ± 2kV A
4 ESD Air discharge ± 15kV A IEC/EN60601-1-2;
YY9706. 102;
IEC/EN61000-4-2;
GB/T 17626.2.
Contact discharge ± 8kV A
5 EFT/B Test voltage ±2kV
Burst frequency 100kHz
A IEC/EN60601-1-2;
YY9706. 102;
IEC/EN61000-4-4;
GB/T 17626.4.
6 DIP Dropped to 0%Ut ,last 5000ms(250cycle) B IEC/EN60601-1-2;
YY9706. 102;
IEC/EN61000-4-3;
GB/T 17626.3.
Dropped to 70%Ut last 500ms(25 cycle) A@230Vac
B@100Vac
Dropped to 0%Ut ,last 20ms(1 cycle) A
Dropped to0%Ut ,last 10ms(0.5 cycle) A
7 RS Test frequency:80MHz~2700MHz
Field intensity:10V/m
Amplitude modulation:80%AM(1KHz)
A IEC/EN60601-1-2;
YY9706. 102;
IEC/EN61000-4-3;
GB/T 17626.3.
8 CS Test frequency:0. 15MHz~80MHz
Field intensity:6Vrms
Amplitude modulation:80%AM(1kHz)
A IEC/EN60601-1-2;
YY9706. 102;
IEC/EN61000-4-6;
GB/T 17626.6.
9 THD Class A(in system) / IEC/EN60601-1-2;
YY9706. 102;
IEC/EN61000-3-2;
GB 17625. 1.
10 Voltage
Fluctuation
And Flicker
Pst≤1.0;Plt≤0.65;Relative steady-state voltage
variation dc under3.3%;Maximum relative voltage
variation (Dmax) under4%
/ IEC/EN60601-1-2;
YY9706. 102;
IEC/EN61000-3-3;
GB/T 17625.2.
11 Power
Frequency
Magnetic Field
30A/m A IEC/EN60601-1-2;
YY9706. 102;
IEC/EN61000-4-8;
GB/T 17626.8.


Note:

 

Performance criterion A: Normal performance within limits in this specification.

 

Performance criterion B: Temporary loss of some functions or degradation of performance. The recovering performance of whichwithout operator intervention.

 

Performance criterion C: Temporary loss of function or degradation of performance .The recovering performance of which requires operator intervention.

 

Performance criterion D: Loss of function or degradation of performance which is not recoverable .Owing to damage of hardware software or loss of data.


SAFETY REQUIREMENT

 

1. Safety: Accord With.

The power supply is designed for indoor use to meet IEC 60601-1/UL60601-1and EN 60601-1standards and for the following safety regulations.


    \ Item Country Standard
UL USA UL60601-1
CE Europe EN60601-1
CB Worldwide IEC60601-1
TUV Germany IEC60601-1
NRTL CUSA

IEC60601-1/UL60601-1

GS Germany EN60601-1
BS England EN60601-1
SAA Australia AS/NZS60601. 1


2. Dielectric Strength Hi-Pot:

The primary to secondary: 4000Vac 5mA for 60 seconds.


MECHANICAL SIZE


EU plug size: L 45.10 x W 40.20 x H 23.20m


123


US plug size: L 45.10 x W 40.20 x H 23.20mm


456


CN plug size: L 45.10 x W 40.20 x H 23.20mm



789


1. Can I visit the factory? 
Our factory is located in Shenzhen, Guangdong Province. We welcome friends from all over the world to visit our factory and discuss cooperation at any time.  
2. Do you have a R&D department? 
Yes, our R&D deparment is more than 30 people. We can design the medical power supply base on our customer's requirement.
3. Which countries' overseas customers do we mainly cooperate with? 
Our customers are mainly the United States, Germany, France, japan etc. 
4. Can you draw 3D design renderings? 
Our company can provide 3D design service, which is a fee service. Once the customer confirms the order, this fee can be deducted from the order payment. 
5. Do you have a third-party factory inspection report? 
Our company has SGS factory inspection report.