Leave Your Message
Products Categories
Featured Products

180W Open Frame Six Output Medical Power Supply 24V 12V5V 12V -12V +110V ACMM180

It has good electromagnetic compatibility and meets the safety requirements of medical equipment.

    PRODUCT PICTURE

    1.1 ACMM180

    PRODUCT PICTURE (1)83x

    1.2 ACMM180A

    PRODUCT PICTURE (2)rmt

    1.3 ACMM180B

    PRODUCT PICTURE (3)mun

    1.4 ACMM180C

    PRODUCT PICTURE (4)yzh

    1.5 ACMM180D

    PRODUCT PICTURE (5)sit

    SERIES TABLE

    ACMM180X Typical Parameter Table

    Voltage

    Output

     

    V1

    V2

    V3

    V4

    V5

    V6

    ACMS43-

    120

     

    +24V

    +12V

    +5V

    +12V

    -12V

    +110V

    +12V

    Current

    0-4A

    0.3-3A

    0.5-3A

    0-1A

    0-1A

    0-0.1A

    0-4.2A

    ACMM180

     

    ACMM180A

     

    ACMM180B

    ACMM180C

    ACMM180D

     

    PRODUCT OVERVIEW

    This power supply is a multi-channel output AC/DC power supply, the whole power supply adopts the latest circuit design, with compact structure, reliable performance, the whole machine high precision voltage regulation characteristics. Output with short circuit protection, over current protection, over voltage protection and other functions. 

    It has good electromagnetic compatibility and meets the safety requirements of medical equipment.

    STANDARDS REFERENCE

    GB2423.1 Basic environmental test procedures for electrical and electronic products -- Test Ad: low temperature test method; 

    GB2423.2 Basic environmental test procedures for electrical and electronic products -- Test Bd: high temperature test method; 

    GB2423.9 Basic environmental test procedures for electrical and electronic products -- Test Cb: constant damp heat test method; 

    GB2423.10 Basic environmental test procedures for electrical and electronic products -- Test Fc: vibration test method; 

    GB 9706.1 (IDT IEC60601-1) medical electrical equipment - Part 1: Safety general requirements; 

    YY 0505(IDT IEC60601-1-2) medical electrical equipment - Part 1-2: Safety common requirements juxtaposed standards: electromagnetic compatibility requirements and tests.

    Electromagnetic Compatiblity

    Numbe

    Item

    Specifications

    Class

    Standards

    1

    (CE)

    CLASS B

    /

    IEC/EN60601-1-2; YY0505

    GB4824; EN55011;

    FCC Part 18

    2

    (RE)

    CLASS B

    /

    IEC/EN60601-1-2; YY0505

    GB4824; EN55011;

    FCC Part 18

    3

    (SURGE)

    Line to line±1KV

    A

    IEC/EN60601-1-2; YY0505

    IEC/EN61000-4-5; GB17626.5

     

     

    Line to GND±2KV

    A

     

    4

    (ESD)

    Air discharge±15KV

    A

    IEC/EN60601-1-2; YY0505

    IEC/EN61000-4-2; GB17626.2

     

     

    Contact discharge±8KV

    A

     

    5

    (EFT/B)

    ±2KV (BURST FREQUENCY=100KHZ)

    A

    IEC/EN60601-1-2; YY0505

    IEC/EN61000-4-4; GB17626.4

    6

    (DIP)

    Dropped to 0%Ut,last 5000ms(250cycle)

    B

    IEC/EN60601-1-2;

    YY0505

    IEC/EN61000-4-11; GB17626.11

    Dropped to 30%Ut,last 500ms(25 cycle)

    B

     

    Dropped to 0%Ut,last 20ms(1 cycle)

    B

     

    Dropped to0%Ut,last 10ms(0.5 cycle)

    A

     

    7

    (RS)

    Test frequency:80MHz~2700MHz;

    Field intensity:10V/m;80%AM(1KHz)

    Amplitude modulation:80%AM(1KHz)

    A

    IEC/EN60601-1-2;

    YY0505

    IEC/EN61000-4-3; GB17626.3

    8

    (CS)

    Test frequency:0.15MHz~80MHz;

    Field intensity:6Vrms;

    Amplitude modulation:80%AM(1KHz)

    A

    IEC/EN60601-1-2;

    YY0505

    IEC/EN61000-4-6; GB17626.6

    9

    (THD)

    CLASSA(in system)

    /

    IEC/EN60601-1-2; YY0505

    IEC/EN61000-3-2; GB17625.1

    10

    Voltage

    Fluctuation and Flicker

    Pst≤1.0;Plt≤0.65;Relative steady-state voltage variation dc under3.3%;Maximum relative voltage variation (dmax) under4%

    /

    IEC/EN60601-1-2;

    YY0505

    IEC/EN61000-3-3; GB17625.2

    11

    Power Frequency Magnetic Field

    30A/m

    A

    IEC/EN60601-1-2; YY0505

    IEC/EN61000-4-8; GB17626.8

    Class A: The power supply can be operated normal.
    Class B: The power supply temporary decline or loss of function or performance but free recover ability. 
    Class C: The power supply temporary decline or loss of function or performance but force recover ability.
    Class D: The power supply loss of function or performance forever.

    OUTLINE

    Number

    Item

    Specifications

    Note

    1

    The failure to isolate

    After the power module fails, there is no output. The power module is reliably isolated and does not cause any damage to the device or personnel

    If a power module fails, the mains power supply system cannot be affected

    2

    Acoustic noise

    ≦45dB(A), test distance: 1m

     

    Mechanical Requirement

    ACMM180 L*W*H=225.0*118.0*35.0Max.( Unit: mm)
    ACMM180 LWH=225.0118.035.0Max.( Unit mm)
    ACMM180A L*W*H=294*123*55mm(max)
    ACMM180 LWH=225jmt
    ACMM180B L*W*H=294.5*136.9*51mm(max)
    ACMM180 LWH=225od1
    ACMM180C/ ACMM180D L*W*H=362.5*126.8*58mm(max)
    ACMM180 LWH=225zmb
    The products should be stored in the packaging box when not in use. The ambient temperature of the warehouse is -40 ~ +85℃, the relative humidity is 10% ~ 90%, and the harmful gas, flammable and explosive products and corrosive chemicals are not allowed in the warehouse, and there is no strong mechanical vibration, impact and strong magnetic field. The packing case shall be placed at least 20cm above the ground and at least 50cm away from the wall, heat source, window or air. The storage period under this condition is generally 2 years. After more than 2 years, it shall be inspected again.

    Label

    The products should be stored in the packaging box when not in usekh8The products should be stored in the packaging box when not in use4v9The products should be stored in the packaging box when not in usev5l
    The products should be stored in the packaging box when not in usezkeThe products should be stored in the packaging box when not in usem0nThe products should be stored in the packaging box when not in uset49
    The products should be stored in the packaging box when not in useg2i

    The packing case is marked with the product name, model, manufacturer's logo, manufacturer's quality department's inspection certificate, manufacturing date, etc.

    The product specification and attached list are attached in the packing case.