150W Medical Power Adapter AC Input Full Range Portable Indoor Medical Equipment Power Adaptor LXCP150
Output Characteristics
Model Name |
Output Voltage(V) |
Rated Load (A) |
Output Range(V) |
Output Power(W) |
|
LXCP150-120 |
LXCP150(II)-120 |
12.0 |
12.50 |
11.4-12.6 |
150.0 |
LXCP150-135 |
LXCP150(II)-135 |
13.5 |
11.11 |
12.8-14.2 |
150.0 |
LXCP150-150 |
LXCP150(II)-150 |
15.0 |
10.00 |
14.2-15.8 |
150.0 |
LXCP150-168 |
LXCP150(II)-168 |
16.8 |
8.93 |
16.0-17.6 |
150.0 |
LXCP150-180 |
LXCP150(II)-180 |
18.0 |
8.33 |
17.1-18.9 |
150.0 |
LXCP150-190 |
LXCP150(II)-190 |
19.0 |
7.90 |
18.1-19.9 |
150.0 |
LXCP150-200 |
LXCP150(II)-200 |
20.0 |
7.50 |
19.0-21.0 |
150.0 |
LXCP150-240 |
LXCP150(II)-240 |
24.0 |
6.25 |
23.5-24.5 |
150.0 |
LXCP150-260 |
LXCP150(II)-260 |
26.0 |
5.77 |
25.5-26.5 |
150.0 |
LXCP150-280 |
LXCP150(II)-280 |
28.0 |
5.36 |
27.4-28.5 |
150.0 |
LXCP150-300 |
LXCP150(II)-300 |
30.0 |
5.00 |
29.4-30.6 |
150.0 |
LXCP150-320 |
LXCP150(II)-320 |
32.0 |
4.68 |
31.4-32.6 |
150.0 |
LXCP150-340 |
LXCP150(II)-340 |
34.0 |
4.41 |
33.3-34.7 |
150.0 |
LXCP150-360 |
LXCP150(II)-360 |
36.0 |
4.17 |
35.3-36.7 |
150.0 |
LXCP150-380 |
LXCP150(II)-380 |
38.0 |
3.95 |
37.2-38.8 |
150.0 |
LXCP150-400 |
LXCP150(II)-400 |
40.0 |
3.75 |
39.2-40.8 |
150.0 |
LXCP150-420 |
LXCP150(II)-420 |
42.0 |
3.57 |
41.1-42.9 |
150.0 |
LXCP150-440 |
LXCP150(II)-440 |
44.0 |
3.40 |
43.1-44.9 |
150.0 |
LXCP150-460 |
LXCP150(II)-460 |
46.0 |
3.26 |
45.0-47.0 |
150.0 |
LXCP150-480 |
LXCP150(II)-480 |
48.0 |
3.20 |
47.0-49.0 |
153.6 |
Application
Electromagnetic Compatiblity
Numbe |
Item |
Specifications |
Class |
Standards |
1 |
(CE) |
CLASS B |
/ |
IEC/EN60601-1-2; YY0505 GB4824; EN55011; FCC Part 18 |
2 |
(RE) |
CLASS B |
/ |
IEC/EN60601-1-2; YY0505 GB4824; EN55011; FCC Part 18 |
3 |
(SURGE) |
Line to line±1KV |
A |
IEC/EN60601-1-2; YY0505 IEC/EN61000-4-5; GB17626.5 |
|
|
Line to GND±2KV |
A |
|
4 |
(ESD) |
Air discharge±15KV |
A |
IEC/EN60601-1-2; YY0505 IEC/EN61000-4-2; GB17626.2 |
|
|
Contact discharge±8KV |
A |
|
5 |
(EFT/B) |
±2KV (BURST FREQUENCY=100KHZ) |
A |
IEC/EN60601-1-2; YY0505 IEC/EN61000-4-4; GB17626.4 |
6 |
(DIP) |
Dropped to 0%Ut,last 5000ms(250cycle) |
B |
IEC/EN60601-1-2; YY0505 IEC/EN61000-4-11; GB17626.11 |
Dropped to 30%Ut,last 500ms(25 cycle) |
B |
|
||
Dropped to 0%Ut,last 20ms(1 cycle) |
B |
|
||
Dropped to0%Ut,last 10ms(0.5 cycle) |
A |
|
||
7 |
(RS) |
Test frequency:80MHz~2700MHz; Field intensity:10V/m;80%AM(1KHz) Amplitude modulation:80%AM(1KHz) |
A |
IEC/EN60601-1-2; YY0505 IEC/EN61000-4-3; GB17626.3 |
8 |
(CS) |
Test frequency:0.15MHz~80MHz; Field intensity:6Vrms; Amplitude modulation:80%AM(1KHz) |
A |
IEC/EN60601-1-2; YY0505 IEC/EN61000-4-6; GB17626.6 |
9 |
(THD) |
CLASSA(in system) |
/ |
IEC/EN60601-1-2; YY0505 IEC/EN61000-3-2; GB17625.1 |
10 |
Voltage Fluctuation and Flicker |
Pst≤1.0;Plt≤0.65;Relative steady-state voltage variation dc under3.3%;Maximum relative voltage variation (dmax) under4% |
/ |
IEC/EN60601-1-2; YY0505 IEC/EN61000-3-3; GB17625.2 |
11 |
Power Frequency Magnetic Field |
30A/m |
A |
IEC/EN60601-1-2; YY0505 IEC/EN61000-4-8; GB17626.8 |