90W Medical Adapter DC Desktop Medical Power Supply Adapter LXCP96

Test condition:Under nominal voltage and rated load, the ripple and noise are as follows when measure with max. bandwidth of 20MHz and Parallel 10uF/0.1uF, crossed connected at testing point. Ripple and noise(max.) less than 200mVp-p.

    LXCP96-aaa/LXCP96-aaaG/LXCP96(II)-aaa
    -LXCP= Longxc/-LXCP= Longxc medical adapter
    -96/96(II)=/-96/96(II)=Name of the series
    -aaa="090"-"480"。"090"9.0V," "120"12.0V,""135"13.5V,""142"14.2V,""150"15.0V,"168"16.8V, "180"18.0V, "190"19.0V, "200"20.0V, "220"22.0V, "240"24.0V,"260"26.0V, "280"28.0V,"300"30.0V, "320"32.0V, "340"34.0V, "360"36.0V, "380"38.0V, "400"40.0V, "420"42.0V, "440"44.0V, "460"46.0V, "480"48.0V。
    -aaa="090"-"480"stands for the output voltage."090"means 9.0V,"120"means 12.0V,"135"means 13.5V,"142"means 14.2V,"150"means 15.0V, "168"means 16.8V,"180"means 18.0V,"190"means 19.0V,"200"means 20.0V,"220"means 22.0V,"240"means 24.0V,"260"means 26.0V,"280"means 28.0V,"300"means 30.0V,"320"means 32.0V,"340"means 34.0V,"360"means 36.0V,"380"means 38.0V,"400"means 40.0V,"420"means 42.0V,"440"means 44.0V,"460"means 46.0V,"480"means 48.0V.
    -G:“G”,“G”,“G”.
    -G: The tail "G" is only used in class I power supply. The tail "G" indicates that the power supply is negatively grounded, while the absence of this "G" means that the negative is not grounded in the conventional model.

    parameter

    Feature
    Model: LXCP96
    ClassⅠ&Ⅱ Construction
    DC output voltage: 9-48Vdc
    Peak power output: 160W
    Single Output with DC Cable
    Size(mm): 144.0(L)*58.0(W)*35.0(H)
    C8 or C14 AC Input Plug

    Model

    Output Voltage

    Output Current

    Output Power

    LXCP96-090

    9V

    7.60A

    68.4W

    LXCP96-120

    12V

    7.60A

    91.2W

    LXCP96-135

    13.5V

    6.66A

    90W

    LXCP96-142

    14.2

    6.33A

    90W

    LXCP96-150

    15V

    6.00A

    90W

    LXCP96-168

    16.8V

    5.35A

    90W

    LXCP96-180

    18V

    5.00A

    90W

    LXCP96-190

    19V

    4.73A

    90W

    LXCP96-200

    20V

    4.50A

    90W

    LXCP96-220

    22V

    4.10A

    90W

    LXCP96-240

    24V

    3.75A

    90W

    LXCP96-260

    26V

    3.46A

    90W

    LXCP96-280

    28V

    3.21A

    90W

    LXCP96-300

    30V

    3.00A

    90W

    LXCP96-320

    32V

    2.81A

    90W

    LXCP96-340

    34V

    2.64A

    90W

    LXCP96-360

    36V

    2.50A

    90W

    LXCP96-380

    38V

    2.36A

    90W

    LXCP96-400

    40V

    2.25A

    90W

    LXCP96-420

    42V

    2.14A

    90W

    LXCP96-440

    44V

    2.04A

    90W

    LXCP96-460

    46V

    1.95A

    90W

    LXCP96-480

    48V

    1.90A

    91.2W

    MECHANICAL

    Turn On Delay Time:
    3 second Max.at 220Vac input and output rated load.
    Rise Time:
    50ms max.at 115Vac input and output rated load.
    Hold Up Time:
    10ms min.at 115Vac input and output rated Load.
    Efficiency:
    85% min, at 115/230Vac input voltage, rated load.

    FAQ