Leave Your Message
Products Categories
Featured Products

LXCP30A 15V 2A 30W Power Supply (Input AC 100V-240V, Output DC 15 Volt 2 Amp 30 Watt) Adapter Transformer Converter DC 5.5mm x 2.1mm / 5.5mm x 2.5mm

  • Universal AC/DC Adapter: Input 100-240V / Output 15V 2A / max wattage is 30W.
  • Multiple uses,Work for 15V dc Devices at Max 2 Ampere 30Watt (300mA 500mA 1A 1.2A 1.4A 1.5A 2Amp , all are Suitable.
  • Note: The power adapter should be used indoors to avoid rain and sun.
  • After-sales guarantee:The products are sold after strict testing.If you have any quality problems, please contact us.
  • When purchasing, please confirm whether the DC jack of your device is the same.
  • Model: LXCP30A
  • Total watt: 30W

INPUT CHARACTERISTICS

Model name

Rated output voltage(Vdc)

Output current(A)

Rated output power(W)

LXCP30A-050b

5.0

4.00

20.0

LXCP30A-075b

7.5

4.00

30.0

LXCP30A-090b

9.0

3.33

30.0

LXCP30A-120b

12.0

2.50

30.0

LXCP30A-126b

12.6

2.50

31.5

LXCP30A-150b

15.0

2.00

30.0

LXCP30A-168b

16.8

1.78

30.0

LXCP30A-180b

18.0

1.67

30.0

LXCP30A-190b

19.0

1.58

30.0

LXCP30A-200b

20.0

1.50

30.0

LXCP30A-240b

24.0

1.30

31.2

INPUT VOLTAGE & FREQUENCY

 

Minimum

Nominal

Maximum

Input Voltage

90Vac

100-240Vac

264Vac

Input Frequency

47Hz

50Hz/60Hz

63Hz

INPUT CURRENT

The maximum input current is max 0.8A at 240Vac.

INRUSH CURRENT

The inrush current will not exceed 50A at 264Vac input for a cold start at 25℃.

STATIC LOSS 

The static loss is less than 0.5W at normal input voltage.

OUTPUT CHARACTERISTICS

Item

Model number

OUTPUT CHARACTERISTICS

 

LXCP30A series

Rated output

voltage(V)

Output voltage range(V)

Rated output current(A)

Rated output power(W)

Over current protection(A)

Over voltage protection(V)

Efficiency

(%)

Model number

LXCP30A-050

5.0

4.40~5.60

4.00

20.0

≤7.0

≤10.0

70

 

LXCP30A-075

7.5

6.90~8.10

4.00

30.0

≤6.0

≤14.5

70

 

LXCP30A-090

9.0

8.40~9.60

3.33

30.0

≤5.0

≤16.0

72

 

LXCP30A-120

12.0

11.40~12.60

2.50

30.0

≤4.0

≤20.0

80

 

LXCP30A-126

12.6

12.20~13.00

2.50

31.5

≤4.0

≤20.0

80

 

LXCP30A-150

15.0

14.40~15.60

2.00

30.0

≤4.0

≤22.0

80

 

 

LXCP30A-168

16.8

16.20~17.40

1.78

30.0

≤3.0

≤22.4

80

 

LXCP30A-180

18.0

17.40~18.60

1.67

30.0

≤2.6

≤25.0

80

 

LXCP30A-190

19.0

18.40~19.60

1.58

30.0

≤2.5

≤26.0

80

 

LXCP30A-200

20.0

19.40~20.60

1.50

30.0

≤2.3

≤28.0

80

 

LXCP30A-240

24.0

23.40~24.60

1.30

31.2

≤2.0

≤35.0

80

load regulation

±5%

voltage regulation

±3%

overshoot

≤5%

Hold up time

≥10 mS

Ripple and noise

≤200mV (measured by 20MHz bandwidth oscilloscope and terminated each output with a 0.1uF ceramic capacitor and a10uF aluminum electrolytic capacitor)

Over temperature protection

The power supply shall go into stop modeWhen the IC's temperature is over its trigger point and when IC temperature is lower than regulation value the power supply shall be self-recovering.

Short circuit protection

The power supply shall withstand continuous current of short circuit on output no any damage and when the fault condition is removed, the power supply shall be self-recovering.

ENVIRONMENTAL REQUIREMENTS

OPERATING CONDITION

The power supply shall be compliant with each item in this specification for the following environmental conditions.

Ambient Temperature

-10℃~40℃

Relative Humidity

20%~90%

STORAGE CONDITION

Ambient Temperature

-20℃~80℃

Relative Humidity

10%~90%

Protection Function

MTBF

The power supply shall have a minimum predicted MTBF(MIL-STD-217F) of 100000 hours at normal operation condition and normal use.

WEIGHT

The weight of the power supply shall be about 120g.

SAFETY STANDARD

The power supply is designed for indoor use to meet IEC 60601-1 and EN 60601-1standards and for the following safety regulations.

Electromagnetic Compatiblity

Number

Item

Specifications

Class

Standards

1

CE

CLASS B

/

IEC/EN60601-1-2

YY0505

GB4824

EN55011

FCC Part 18

GB4824

2

RE

CLASS B

/

IEC/EN60601-1-2

YY0505

GB4824

EN55011

FCC Part 18

3

SURGE

Line to line±1KV

A

IEC/EN60601-1-2

YY0505

IEC/EN61000-4-5

GB17626.5

 

 

Line to GND±2KV

A

 

4

ESD

Air discharge±15KV

A

IEC/EN60601-1-2

YY0505

IEC/EN61000-4-2

GB17626.2

 

 

Contact discharge±8KV

A

 

5

EFT/B

±2KV (BURST FREQUENCY=100KHz)

A

IEC/EN60601-1-2

YY0505

IEC/EN61000-4-4

GB17626.4

6

DIP

Dropped to 0%Ut,last 5000ms(250cycle)

B

IEC/EN60601-1-2

YY0505

IEC/EN61000-4-11

GB17626.11

 

 

Dropped to 30%Ut,last 500ms(25 cycle)

B

 

 

 

Dropped to 0%Ut,last 20ms(1 cycle)

B

 

 

 

Dropped to 0%Ut,last 10ms(0.5 cycle)

A

 

7

RS

Test frequency:80MHz~2700MHz;

Field intensity:10V/m;

Amplitude modulation:80%AM(1KHz)

A

IEC/EN60601-1-2

YY0505

IEC/EN61000-4-3

GB17626.3

8

CS

Test frequency:0.15MHz~80MHz;

Field intensity:6V;

Amplitude modulation:80%AM(1KHz)

A

IEC/EN60601-1-2

YY0505

IEC/EN61000-4-6

GB17626.6

9

THD

CLASS A (in system)

/

IEC/EN60601-1-2

YY0505

IEC/EN61000-3-2

GB17625.1

10

Voltage

Fluctuation and Flicker

Pst≤1.0;Plt≤0.65;Relative steady-state voltage variation dc under3.3%;Maximum relative voltage variation (dmax) under4%

/

IEC/EN60601-1-2

YY0505

IEC/EN61000-3-3

GB17625.2

11

Power Frequency Magnetic Field

30A/m

A

IEC/EN60601-1-2

YY0505

IEC/EN61000-4-8

GB17626.8

Performance criterion A: Normal performance within limits in this specification. 
Performance criterion B: Temporary loss of some functions or degradation of performance. The recovering performance of which without operator intervention.
Performance criterion C: Temporary loss of function or degradation of performance .The recovering performance of which requires operator intervention.
Performance criterion D: Loss of function or degradation of performance which is not recoverable .Owing to damage of hardware , software, or loss of data.

Safety: accord with

The power supply is designed for indoor use to meet ICE 60601-1 and EN 60601-1 standards, and design for the following safety regulations.
 

ITEM

COUNTRY

STANDARD

UL

USA

UL 60950-1/UL 60601-1

CE

EUROPE

EN 60950/EN60601-1/CISPR 22

CB

WORLDWIDE

IEC 60601-1

TUV

GERMANY

IEC 60601-1

NRTL

CUSA

IEC 60601-1/UL 60601-1

GS

GERMANY

EN 60601-1

BS

ENGLAND

EN 60601-1

FCC

USA

Part 15 Subpart B Class B

CCC

CHINA

GB 4943/GB 9254/BG 17625

Primary to Secondary: 4KVac 5mA for 60 seconds
According to the class II with Leakage current less than 100uA.

Mechanical Requirement

AC Plug: CN  L*W*H=83.38*43.5*57.0mm
agds (1)s9k
AC Plug: EU  L*W*H=83.38*43.5*67.2mm
agds (2)0be
AC Plug: UK  L*W*H=83.38*49.0*60.0mm
agds (3)58g
AC Plug: US  L*W*H=83.38*43.5*57.0mm
agds (4)f9a
AC Plug: AUS  L*W*H=83.38*43.5*56.3mm
agds (5)92q

Optional input plug

See the schematic diagram below.

ajkfg (1)3h9ajkfg (2)j4h

DC PLUG FIGURE

J@KWE%C2%D~PB3~M(7GYPEFtn2
Note: Details are selected from the LXC_ Wire Library drawing XLS file

NAMEPLATE (UNIT: mm)