LXCP30A 15V 2A 30W Power Supply (Input AC 100V-240V, Output DC 15 Volt 2 Amp 30 Watt) Adapter Transformer Converter DC 5.5mm x 2.1mm / 5.5mm x 2.5mm
INPUT CHARACTERISTICS
Model name |
Rated output voltage(Vdc) |
Output current(A) |
Rated output power(W) |
LXCP30A-050b |
5.0 |
4.00 |
20.0 |
LXCP30A-075b |
7.5 |
4.00 |
30.0 |
LXCP30A-090b |
9.0 |
3.33 |
30.0 |
LXCP30A-120b |
12.0 |
2.50 |
30.0 |
LXCP30A-126b |
12.6 |
2.50 |
31.5 |
LXCP30A-150b |
15.0 |
2.00 |
30.0 |
LXCP30A-168b |
16.8 |
1.78 |
30.0 |
LXCP30A-180b |
18.0 |
1.67 |
30.0 |
LXCP30A-190b |
19.0 |
1.58 |
30.0 |
LXCP30A-200b |
20.0 |
1.50 |
30.0 |
LXCP30A-240b |
24.0 |
1.30 |
31.2 |
INPUT VOLTAGE & FREQUENCY
Minimum |
Nominal |
Maximum |
|
Input Voltage |
90Vac |
100-240Vac |
264Vac |
Input Frequency |
47Hz |
50Hz/60Hz |
63Hz |
INPUT CURRENT
The maximum input current is max 0.8A at 240Vac.
INRUSH CURRENT
The inrush current will not exceed 50A at 264Vac input for a cold start at 25℃.
STATIC LOSS
The static loss is less than 0.5W at normal input voltage.
OUTPUT CHARACTERISTICS
Item |
Model number |
OUTPUT CHARACTERISTICS |
||||||
|
LXCP30A series |
Rated output voltage(V) |
Output voltage range(V) |
Rated output current(A) |
Rated output power(W) |
Over current protection(A) |
Over voltage protection(V) |
Efficiency (%) |
Model number |
LXCP30A-050 |
5.0 |
4.40~5.60 |
4.00 |
20.0 |
≤7.0 |
≤10.0 |
70 |
|
LXCP30A-075 |
7.5 |
6.90~8.10 |
4.00 |
30.0 |
≤6.0 |
≤14.5 |
70 |
|
LXCP30A-090 |
9.0 |
8.40~9.60 |
3.33 |
30.0 |
≤5.0 |
≤16.0 |
72 |
|
LXCP30A-120 |
12.0 |
11.40~12.60 |
2.50 |
30.0 |
≤4.0 |
≤20.0 |
80 |
|
LXCP30A-126 |
12.6 |
12.20~13.00 |
2.50 |
31.5 |
≤4.0 |
≤20.0 |
80 |
|
LXCP30A-150 |
15.0 |
14.40~15.60 |
2.00 |
30.0 |
≤4.0 |
≤22.0 |
80
|
|
LXCP30A-168 |
16.8 |
16.20~17.40 |
1.78 |
30.0 |
≤3.0 |
≤22.4 |
80 |
|
LXCP30A-180 |
18.0 |
17.40~18.60 |
1.67 |
30.0 |
≤2.6 |
≤25.0 |
80 |
|
LXCP30A-190 |
19.0 |
18.40~19.60 |
1.58 |
30.0 |
≤2.5 |
≤26.0 |
80 |
|
LXCP30A-200 |
20.0 |
19.40~20.60 |
1.50 |
30.0 |
≤2.3 |
≤28.0 |
80 |
|
LXCP30A-240 |
24.0 |
23.40~24.60 |
1.30 |
31.2 |
≤2.0 |
≤35.0 |
80 |
load regulation |
±5% |
|||||||
voltage regulation |
±3% |
|||||||
overshoot |
≤5% |
|||||||
Hold up time |
≥10 mS |
|||||||
Ripple and noise |
≤200mV (measured by 20MHz bandwidth oscilloscope and terminated each output with a 0.1uF ceramic capacitor and a10uF aluminum electrolytic capacitor) |
|||||||
Over temperature protection |
The power supply shall go into stop modeWhen the IC's temperature is over its trigger point and when IC temperature is lower than regulation value the power supply shall be self-recovering. |
|||||||
Short circuit protection |
The power supply shall withstand continuous current of short circuit on output no any damage and when the fault condition is removed, the power supply shall be self-recovering. |
ENVIRONMENTAL REQUIREMENTS
OPERATING CONDITION
The power supply shall be compliant with each item in this specification for the following environmental conditions.
Ambient Temperature |
-10℃~40℃ |
Relative Humidity |
20%~90% |
STORAGE CONDITION
Ambient Temperature |
-20℃~80℃ |
Relative Humidity |
10%~90% |
Protection Function
MTBF
The power supply shall have a minimum predicted MTBF(MIL-STD-217F) of 100000 hours at normal operation condition and normal use.
WEIGHT
The weight of the power supply shall be about 120g.
SAFETY STANDARD
The power supply is designed for indoor use to meet IEC 60601-1 and EN 60601-1standards and for the following safety regulations.
Electromagnetic Compatiblity
Number |
Item |
Specifications |
Class |
Standards |
1 |
CE |
CLASS B |
/ |
IEC/EN60601-1-2 YY0505 GB4824 EN55011 FCC Part 18 GB4824 |
2 |
RE |
CLASS B |
/ |
IEC/EN60601-1-2 YY0505 GB4824 EN55011 FCC Part 18 |
3 |
SURGE |
Line to line±1KV |
A |
IEC/EN60601-1-2 YY0505 IEC/EN61000-4-5 GB17626.5 |
|
|
Line to GND±2KV |
A |
|
4 |
ESD |
Air discharge±15KV |
A |
IEC/EN60601-1-2 YY0505 IEC/EN61000-4-2 GB17626.2 |
|
|
Contact discharge±8KV |
A |
|
5 |
EFT/B |
±2KV (BURST FREQUENCY=100KHz) |
A |
IEC/EN60601-1-2 YY0505 IEC/EN61000-4-4 GB17626.4 |
6 |
DIP |
Dropped to 0%Ut,last 5000ms(250cycle) |
B |
IEC/EN60601-1-2 YY0505 IEC/EN61000-4-11 GB17626.11 |
|
|
Dropped to 30%Ut,last 500ms(25 cycle) |
B |
|
|
|
Dropped to 0%Ut,last 20ms(1 cycle) |
B |
|
|
|
Dropped to 0%Ut,last 10ms(0.5 cycle) |
A |
|
7 |
RS |
Test frequency:80MHz~2700MHz; Field intensity:10V/m; Amplitude modulation:80%AM(1KHz) |
A |
IEC/EN60601-1-2 YY0505 IEC/EN61000-4-3 GB17626.3 |
8 |
CS |
Test frequency:0.15MHz~80MHz; Field intensity:6V; Amplitude modulation:80%AM(1KHz) |
A |
IEC/EN60601-1-2 YY0505 IEC/EN61000-4-6 GB17626.6 |
9 |
THD |
CLASS A (in system) |
/ |
IEC/EN60601-1-2 YY0505 IEC/EN61000-3-2 GB17625.1 |
10 |
Voltage Fluctuation and Flicker |
Pst≤1.0;Plt≤0.65;Relative steady-state voltage variation dc under3.3%;Maximum relative voltage variation (dmax) under4% |
/ |
IEC/EN60601-1-2 YY0505 IEC/EN61000-3-3 GB17625.2 |
11 |
Power Frequency Magnetic Field |
30A/m |
A |
IEC/EN60601-1-2 YY0505 IEC/EN61000-4-8 GB17626.8 |
Safety: accord with
ITEM |
COUNTRY |
STANDARD |
|
□ |
UL |
USA |
UL 60950-1/UL 60601-1 |
■ |
CE |
EUROPE |
EN 60950/EN60601-1/CISPR 22 |
■ |
CB |
WORLDWIDE |
IEC 60601-1 |
□ |
TUV |
GERMANY |
IEC 60601-1 |
□ |
NRTL |
CUSA |
IEC 60601-1/UL 60601-1 |
□ |
GS |
GERMANY |
EN 60601-1 |
□ |
BS |
ENGLAND |
EN 60601-1 |
□ |
FCC |
USA |
Part 15 Subpart B Class B |
□ |
CCC |
CHINA |
GB 4943/GB 9254/BG 17625 |
Mechanical Requirement